Professional Generator Set Manufacturer

Power That Never Stops When Darkness Falls, NovArk Powers Through
Our company was established in 2013 and consists of four branches nationwide. As one of the leading OEM manufacturers of diesel generators in China, we have earned a strong reputation and multiple awards over the years, meeting diverse requests from markets around the world.
Home / All / Diesel Generator Sets / Silent Diesel Generators / Cummins Brand / CCEC Cummins Series Industrial Diesel Generator Set 200-2400kW Prime and Standby Power

CCEC Cummins Series Industrial Diesel Generator Set 200-2400kW Prime and Standby Power

CCEC Cummins Series Industrial Diesel Generator Set 200-2400kW Prime and Standby Power
CCEC Cummins Series Industrial Diesel Generator Set 200-2400kW Prime and Standby PowerCCEC Cummins Series Industrial Diesel Generator Set 200-2400kW Prime and Standby PowerCCEC Cummins Series Industrial Diesel Generator Set 200-2400kW Prime and Standby PowerCCEC Cummins Series Industrial Diesel Generator Set 200-2400kW Prime and Standby PowerCCEC Cummins Series Industrial Diesel Generator Set 200-2400kW Prime and Standby Power
Share
CategoriesCummins Brand
BrandNovArk Power
Product SpecificationsQD-CCEC
Rated power200 - 2400 kW
Standby power220 - 2640 kW
Rated voltage400/230 V, adjustable
Rated frequency50 / 60 Hz
Power factor0.8
Engine brandCCEC Cummins (Chongqing Cummins)
Engine familiesQSM11 / QSNT / QSK19 / KTA19 / QSK38 / KTA38 / KTA50
Cylinders6 / 12 / 16
Displacement14 / 19 / 38 / 50 L
AspirationTurbocharged and aftercooled
AlternatorBrushless, class H, AVR
Control panelAuto start, digital, AMF ready
ConfigurationOpen frame / silent / container
Fuel consumption202 - 217 g/kWh
StandardISO 3046 / ISO 8528
DownloadDownload pdf
Detail Information
CCEC Cummins series industrial diesel generator set, 200 to 2400 kW, open frame configuration

Cummins powered · 200 - 2400 kW

CCEC Cummins Series Diesel Generator Set for Prime and Standby Power

The CCEC Cummins series diesel generator set is built around Chongqing Cummins M, N and K series engines — the QSM11, QSNT, QSK19, KTA19, QSK38, KTA38 and KTA50 families — driving brushless, class H alternators. One platform spans 200 kW to 2400 kW, so a mine camp, a hospital or a 2000 kW data centre standby requirement can be sourced from the same Cummins diesel generator range with one documentation set and one spare parts list.

Every set is assembled on a heavy-gauge skid, wired to an automatic start control panel and load tested before shipment. Open frame, soundproof canopy and containerised versions are available, at 50 Hz or 60 Hz, with voltage matched to the site.

  • 200 - 2400kW series range
  • 7Cummins engine families
  • 6 - 16cylinders, 14 - 50 L
  • 50 / 60Hz, site voltage

Why this platform

Engineered around a genuine Cummins base engine

Matched power train, one supplier

Engine, alternator, coupling, control panel and circuit breaker are selected as a set and tested as a set. No mismatched sub-assemblies to reconcile on site, and a single warranty covers the whole unit.

Fuel consumption from 202 g/kWh

Specific fuel consumption across the range sits between 202 and 217 g/kWh at rated load. On a 1200 kW KTA50 set that difference is measurable over a year of prime power operation.

Service access that respects downtime

Three-side engine access, spin-on filters and a hinged control compartment keep routine service inside a normal maintenance window. Consumables are available through the Cummins global parts network.

Built to ISO 3046 and ISO 8528

Ratings, governing and load acceptance follow ISO 3046 and ISO 8528 practice, with ambient conditions of -10 to 40 degrees Celsius and humidity up to 60 percent as the standard reference.

Enclosure formats

Three enclosure formats, one base engine

Open frame for plant rooms and containerised power stations, soundproof canopy where noise limits apply, and ISO container builds for sea freight. Engine, alternator and control panel stay the same across formats, so spare parts, wiring diagrams and operating procedures carry over from one build to the next.

CCEC Cummins diesel generator set in open frame, silent canopy and containerised formats

Product power parameters

Power range by Cummins engine family

Seven engine families cover the range. Choose the family first, then the rating; the table below shows the envelope each one covers, while the full model list further down gives dimensions, fuel consumption and dry weight for every build.

Engine familyDisplacementCylindersMax power (kW)Typical duty
QSM1114 L6270 - 377Mining drills, plant prime power, mid-size standby
QSNT14 L6265 - 392Construction sites, rental fleets, hospital backup
QSK1919 L6447 - 667Crushers, marine auxiliary, oil field support
KTA1919 L6561 - 660Continuous duty base load, rail depot power
QSK3838 L12730 - 1333Data centres, utility peaking, port operations
KTA3838 L12770 - 1210Industrial base load, mining camps, utilities
KTA5050 L161210 - 1760Large data centres, power stations, marine

Power figures refer to the highest rating available within each family; site conditions, altitude and ambient temperature derate apply.

Complete range

CCEC Cummins genset model list and specifications

Forty standard builds, from 200 kW prime power to 1760 kW maximum output. Higher ratings within the 2400 kW series ceiling are quoted against project specification. Prime and standby ratings are stated at 0.8 power factor; dimensions and weight refer to the open frame set without fuel tank.

Unit modelPrime (kW)Standby (kW)Max (kW)Engine modelCyl.Disp. (L)Fuel (g/kWh)L x W x H (mm)Weight (kg)
QD-263CC210231270QSM11-G16142112750x980x16002300
QD-250CC200220265QSNT-G66142143000x1050x17502600
QD-275CC220242291QSNT-G76142173000x1050x17502700
QD-300CC240264300QSM11-G26142173000x1050x17502700
QD-320CC255280.5321QSM11-G26142173000x1050x17502700
QD-313CC250275325QSNT-G16142113000x1050x17502700
QD-338CC270297330QSM11-G36142113000x1050x17502800
QD-350CC280308358QSNT-G26142103100x1050x17503000
QD-350CC280308350QSM11-G46142103100x1050x17503000
QD-363CC290319360QSM11-G56142103100x1050x17503000
QD-375CC300330377QSM11-G66142103100x1200x18003100
QD-400CC320352392QSNT-G36142053100x1050x17503100
QD-450CC360396448QSNT-G4X6142093100x1050x17503200
QD-450CC360396448QSK19-G156192073300x1400x19703400
QD-450CC360396447QSK19-G146192073300x1400x19703400
QD-500CC400440501QSK19-G136192053600x1400x19703900
QD-575CC460506565QSK19-G126192173600x1500x20004200
QD-588CC470517592QSK19-G66192043600x1500x20004200
QD-650CC520572634QSK19-G46192153600x1500x20004800
QD-688CC550605667QSK19-G116192163600x1500x20005000
QD-750CC600660730QSK38-G812382174300x1700x23506500
QD-813CC650715783QSK38-G712382164500x1800x23508000
QD-910CC728800.8878QSK38-G612382124500x1800x23508000
QD-1008CC806886.6970QSK38-G112382064500x1800x23508500
QD-1144CC9151006.51096QSK38-G212382024500x1800x23509000
QD-1250CC100011001224QSK38-G512382084500x1800x23509000
QD-1350CC108011881333QSK38-G1912382094500x1800x23509000
QD-563CC450495561KTA19-G8E6192093600x1400x19703900
QD-625CC500550610KTA19-G8A6192093600x1500x20004800
QD-682CC545599.5660KTA19-G9A6192093600x1500x20005000
QD-813CC650715770KTA38-G2E12382094500x1800x23508000
QD-938CC750825880KTA38-G5E12382094500x1800x23508500
QD-1063CC850935990KTA38-G7E12382094500x1800x23509000
QD-1125CC9009901100KTA38-G9E12382094500x1800x23509000
QD-1250CC100011001210KTA38-G9A12382094500x1800x23509000
QD-1250CC100011001210KTA50-G3E16502055700x2280x250011000
QD-1375CC110012101320KTA50-G7E16502055700x2280x250011500
QD-1500CC120013201430KTA50-G8E16502055700x2280x250011500
QD-1675CC134014741650KTA50-G15A16502055700x2280x250012000
QD-1875CC150016501760KTA50-G16A16502055700x2280x250012500

Standby ratings are limited to the duration of a utility outage and are not continuous ratings. Voltage and frequency are configured per project. Capacity is verified on a load bank before handover — see how load bank testing works.

CCEC Cummins diesel generator set power range from 200 kW to 2400 kW

Product application scenarios

Where the CCEC Cummins series is specified

01

Mining and quarrying

Prime power for crushers, conveyors and dewatering pumps where the grid is weak or absent. The high-displacement QSK38 and KTA38 families hold load steps without excessive frequency dip.

02

Power plants and utilities

Black start, peaking and station blackout backup. KTA50 units at 1200-1500 kW are commonly paralleled for N+1 station service duty.

03

Marine and port operations

Shipborne auxiliary power, shore-side supply for cold ironing and container terminal backup. Marine configuration options include heat exchangers and classification-ready documentation.

04

Rail and transit depots

Track-side and depot power for maintenance facilities, signalling backup and tunnel construction loads.

05

Oil, gas and petrochemical

Drilling rig power, well-site generation and refinery standby, with spark arrestor and remote radiator options for hazardous locations.

06

Data centres and hospitals

Standby power for critical loads at 10-second start and full load acceptance, with remote monitoring and automatic transfer switch integration.

Industrial diesel generator set applications: mining, power plants, marine, rail, oil and gas, data centres

Testing and handover

Load tested before it leaves the factory

Every set is assembled on its skid, wired to the control panel and run on a load bank before shipment. Insulation resistance and winding checks, governor and AVR setting, safety shutdown verification and a stepped load test are recorded against the serial number, and the test sheet travels with the unit.

Where a project requires it, third-party witness testing, a documented fuel consumption curve and a site acceptance procedure are agreed in the contract.

CCEC Cummins generator set under load bank testing before shipment

Selection questions

Choosing the right rating

What is the difference between prime and standby power on a CCEC Cummins set?

Prime power is the rating the set can deliver continuously with a variable load, and standby power is the higher rating available for the duration of a utility outage. In this range standby output is about ten percent above prime, for example 1200 kW prime and 1320 kW standby on the 50 litre KTA50 platform.

Can the generator set be supplied at 60 Hz or at a non-standard voltage?

Yes. Asia, Africa and Europe are usually served at 50 Hz with 230/400 V three-phase, while the Americas, Japan and Korea are typically 60 Hz at 230/440 V. Voltage, frequency and the alternator winding are specified per project, and the nameplate is issued against the confirmed site data.

How is a set from this range tested before shipment?

Each unit is assembled, wired and run on a load bank at the factory: insulation resistance and winding checks, governor and AVR setting, safety shutdown verification and a load test across the specified rating. Test records travel with the set.

Need a specific rating, voltage or enclosure?

Send the site conditions and load profile. We will confirm the rating from this range, or size a custom build. High power ESP projects such as the 2000 kW set recognised in Hunan follow the same engineering route.

Browse Cummins generator sets
Please send your message to us
*Email
*Phone
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.