Matched power train, one supplier
Engine, alternator, coupling, control panel and circuit breaker are selected as a set and tested as a set. No mismatched sub-assemblies to reconcile on site, and a single warranty covers the whole unit.






Cummins powered · 200 - 2400 kW
The CCEC Cummins series diesel generator set is built around Chongqing Cummins M, N and K series engines — the QSM11, QSNT, QSK19, KTA19, QSK38, KTA38 and KTA50 families — driving brushless, class H alternators. One platform spans 200 kW to 2400 kW, so a mine camp, a hospital or a 2000 kW data centre standby requirement can be sourced from the same Cummins diesel generator range with one documentation set and one spare parts list.
Every set is assembled on a heavy-gauge skid, wired to an automatic start control panel and load tested before shipment. Open frame, soundproof canopy and containerised versions are available, at 50 Hz or 60 Hz, with voltage matched to the site.
Why this platform
Engine, alternator, coupling, control panel and circuit breaker are selected as a set and tested as a set. No mismatched sub-assemblies to reconcile on site, and a single warranty covers the whole unit.
Specific fuel consumption across the range sits between 202 and 217 g/kWh at rated load. On a 1200 kW KTA50 set that difference is measurable over a year of prime power operation.
Three-side engine access, spin-on filters and a hinged control compartment keep routine service inside a normal maintenance window. Consumables are available through the Cummins global parts network.
Ratings, governing and load acceptance follow ISO 3046 and ISO 8528 practice, with ambient conditions of -10 to 40 degrees Celsius and humidity up to 60 percent as the standard reference.
Enclosure formats
Open frame for plant rooms and containerised power stations, soundproof canopy where noise limits apply, and ISO container builds for sea freight. Engine, alternator and control panel stay the same across formats, so spare parts, wiring diagrams and operating procedures carry over from one build to the next.
Product power parameters
Seven engine families cover the range. Choose the family first, then the rating; the table below shows the envelope each one covers, while the full model list further down gives dimensions, fuel consumption and dry weight for every build.
| Engine family | Displacement | Cylinders | Max power (kW) | Typical duty |
|---|---|---|---|---|
| QSM11 | 14 L | 6 | 270 - 377 | Mining drills, plant prime power, mid-size standby |
| QSNT | 14 L | 6 | 265 - 392 | Construction sites, rental fleets, hospital backup |
| QSK19 | 19 L | 6 | 447 - 667 | Crushers, marine auxiliary, oil field support |
| KTA19 | 19 L | 6 | 561 - 660 | Continuous duty base load, rail depot power |
| QSK38 | 38 L | 12 | 730 - 1333 | Data centres, utility peaking, port operations |
| KTA38 | 38 L | 12 | 770 - 1210 | Industrial base load, mining camps, utilities |
| KTA50 | 50 L | 16 | 1210 - 1760 | Large data centres, power stations, marine |
Power figures refer to the highest rating available within each family; site conditions, altitude and ambient temperature derate apply.
Complete range
Forty standard builds, from 200 kW prime power to 1760 kW maximum output. Higher ratings within the 2400 kW series ceiling are quoted against project specification. Prime and standby ratings are stated at 0.8 power factor; dimensions and weight refer to the open frame set without fuel tank.
| Unit model | Prime (kW) | Standby (kW) | Max (kW) | Engine model | Cyl. | Disp. (L) | Fuel (g/kWh) | L x W x H (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|
| QD-263CC | 210 | 231 | 270 | QSM11-G1 | 6 | 14 | 211 | 2750x980x1600 | 2300 |
| QD-250CC | 200 | 220 | 265 | QSNT-G6 | 6 | 14 | 214 | 3000x1050x1750 | 2600 |
| QD-275CC | 220 | 242 | 291 | QSNT-G7 | 6 | 14 | 217 | 3000x1050x1750 | 2700 |
| QD-300CC | 240 | 264 | 300 | QSM11-G2 | 6 | 14 | 217 | 3000x1050x1750 | 2700 |
| QD-320CC | 255 | 280.5 | 321 | QSM11-G2 | 6 | 14 | 217 | 3000x1050x1750 | 2700 |
| QD-313CC | 250 | 275 | 325 | QSNT-G1 | 6 | 14 | 211 | 3000x1050x1750 | 2700 |
| QD-338CC | 270 | 297 | 330 | QSM11-G3 | 6 | 14 | 211 | 3000x1050x1750 | 2800 |
| QD-350CC | 280 | 308 | 358 | QSNT-G2 | 6 | 14 | 210 | 3100x1050x1750 | 3000 |
| QD-350CC | 280 | 308 | 350 | QSM11-G4 | 6 | 14 | 210 | 3100x1050x1750 | 3000 |
| QD-363CC | 290 | 319 | 360 | QSM11-G5 | 6 | 14 | 210 | 3100x1050x1750 | 3000 |
| QD-375CC | 300 | 330 | 377 | QSM11-G6 | 6 | 14 | 210 | 3100x1200x1800 | 3100 |
| QD-400CC | 320 | 352 | 392 | QSNT-G3 | 6 | 14 | 205 | 3100x1050x1750 | 3100 |
| QD-450CC | 360 | 396 | 448 | QSNT-G4X | 6 | 14 | 209 | 3100x1050x1750 | 3200 |
| QD-450CC | 360 | 396 | 448 | QSK19-G15 | 6 | 19 | 207 | 3300x1400x1970 | 3400 |
| QD-450CC | 360 | 396 | 447 | QSK19-G14 | 6 | 19 | 207 | 3300x1400x1970 | 3400 |
| QD-500CC | 400 | 440 | 501 | QSK19-G13 | 6 | 19 | 205 | 3600x1400x1970 | 3900 |
| QD-575CC | 460 | 506 | 565 | QSK19-G12 | 6 | 19 | 217 | 3600x1500x2000 | 4200 |
| QD-588CC | 470 | 517 | 592 | QSK19-G6 | 6 | 19 | 204 | 3600x1500x2000 | 4200 |
| QD-650CC | 520 | 572 | 634 | QSK19-G4 | 6 | 19 | 215 | 3600x1500x2000 | 4800 |
| QD-688CC | 550 | 605 | 667 | QSK19-G11 | 6 | 19 | 216 | 3600x1500x2000 | 5000 |
| QD-750CC | 600 | 660 | 730 | QSK38-G8 | 12 | 38 | 217 | 4300x1700x2350 | 6500 |
| QD-813CC | 650 | 715 | 783 | QSK38-G7 | 12 | 38 | 216 | 4500x1800x2350 | 8000 |
| QD-910CC | 728 | 800.8 | 878 | QSK38-G6 | 12 | 38 | 212 | 4500x1800x2350 | 8000 |
| QD-1008CC | 806 | 886.6 | 970 | QSK38-G1 | 12 | 38 | 206 | 4500x1800x2350 | 8500 |
| QD-1144CC | 915 | 1006.5 | 1096 | QSK38-G2 | 12 | 38 | 202 | 4500x1800x2350 | 9000 |
| QD-1250CC | 1000 | 1100 | 1224 | QSK38-G5 | 12 | 38 | 208 | 4500x1800x2350 | 9000 |
| QD-1350CC | 1080 | 1188 | 1333 | QSK38-G19 | 12 | 38 | 209 | 4500x1800x2350 | 9000 |
| QD-563CC | 450 | 495 | 561 | KTA19-G8E | 6 | 19 | 209 | 3600x1400x1970 | 3900 |
| QD-625CC | 500 | 550 | 610 | KTA19-G8A | 6 | 19 | 209 | 3600x1500x2000 | 4800 |
| QD-682CC | 545 | 599.5 | 660 | KTA19-G9A | 6 | 19 | 209 | 3600x1500x2000 | 5000 |
| QD-813CC | 650 | 715 | 770 | KTA38-G2E | 12 | 38 | 209 | 4500x1800x2350 | 8000 |
| QD-938CC | 750 | 825 | 880 | KTA38-G5E | 12 | 38 | 209 | 4500x1800x2350 | 8500 |
| QD-1063CC | 850 | 935 | 990 | KTA38-G7E | 12 | 38 | 209 | 4500x1800x2350 | 9000 |
| QD-1125CC | 900 | 990 | 1100 | KTA38-G9E | 12 | 38 | 209 | 4500x1800x2350 | 9000 |
| QD-1250CC | 1000 | 1100 | 1210 | KTA38-G9A | 12 | 38 | 209 | 4500x1800x2350 | 9000 |
| QD-1250CC | 1000 | 1100 | 1210 | KTA50-G3E | 16 | 50 | 205 | 5700x2280x2500 | 11000 |
| QD-1375CC | 1100 | 1210 | 1320 | KTA50-G7E | 16 | 50 | 205 | 5700x2280x2500 | 11500 |
| QD-1500CC | 1200 | 1320 | 1430 | KTA50-G8E | 16 | 50 | 205 | 5700x2280x2500 | 11500 |
| QD-1675CC | 1340 | 1474 | 1650 | KTA50-G15A | 16 | 50 | 205 | 5700x2280x2500 | 12000 |
| QD-1875CC | 1500 | 1650 | 1760 | KTA50-G16A | 16 | 50 | 205 | 5700x2280x2500 | 12500 |
Standby ratings are limited to the duration of a utility outage and are not continuous ratings. Voltage and frequency are configured per project. Capacity is verified on a load bank before handover — see how load bank testing works.
Product application scenarios
Prime power for crushers, conveyors and dewatering pumps where the grid is weak or absent. The high-displacement QSK38 and KTA38 families hold load steps without excessive frequency dip.
Black start, peaking and station blackout backup. KTA50 units at 1200-1500 kW are commonly paralleled for N+1 station service duty.
Shipborne auxiliary power, shore-side supply for cold ironing and container terminal backup. Marine configuration options include heat exchangers and classification-ready documentation.
Track-side and depot power for maintenance facilities, signalling backup and tunnel construction loads.
Drilling rig power, well-site generation and refinery standby, with spark arrestor and remote radiator options for hazardous locations.
Standby power for critical loads at 10-second start and full load acceptance, with remote monitoring and automatic transfer switch integration.
Testing and handover
Every set is assembled on its skid, wired to the control panel and run on a load bank before shipment. Insulation resistance and winding checks, governor and AVR setting, safety shutdown verification and a stepped load test are recorded against the serial number, and the test sheet travels with the unit.
Where a project requires it, third-party witness testing, a documented fuel consumption curve and a site acceptance procedure are agreed in the contract.
Selection questions
Prime power is the rating the set can deliver continuously with a variable load, and standby power is the higher rating available for the duration of a utility outage. In this range standby output is about ten percent above prime, for example 1200 kW prime and 1320 kW standby on the 50 litre KTA50 platform.
Yes. Asia, Africa and Europe are usually served at 50 Hz with 230/400 V three-phase, while the Americas, Japan and Korea are typically 60 Hz at 230/440 V. Voltage, frequency and the alternator winding are specified per project, and the nameplate is issued against the confirmed site data.
Each unit is assembled, wired and run on a load bank at the factory: insulation resistance and winding checks, governor and AVR setting, safety shutdown verification and a load test across the specified rating. Test records travel with the set.
Send the site conditions and load profile. We will confirm the rating from this range, or size a custom build. High power ESP projects such as the 2000 kW set recognised in Hunan follow the same engineering route.