Professional Generator Set Manufacturer

Power That Never Stops When Darkness Falls, NovArk Powers Through
Our company was established in 2013 and consists of four branches nationwide. As one of the leading OEM manufacturers of diesel generators in China, we have earned a strong reputation and multiple awards over the years, meeting diverse requests from markets around the world.
Home / All / Diesel Generator Sets / Mobile Diesel Generators / Mobile Diesel Generator Set on Road Trailer for Site and Rental Power

Mobile Diesel Generator Set on Road Trailer for Site and Rental Power

Mobile Diesel Generator Set on Road Trailer for Site and Rental Power
Mobile Diesel Generator Set on Road Trailer for Site and Rental PowerMobile Diesel Generator Set on Road Trailer for Site and Rental PowerMobile Diesel Generator Set on Road Trailer for Site and Rental PowerMobile Diesel Generator Set on Road Trailer for Site and Rental PowerMobile Diesel Generator Set on Road Trailer for Site and Rental Power
Share
CategoriesMobile Diesel Generators
BrandNovArk Power
Product SpecificationsQD-MT
MountingTwo-wheel road trailer with A-frame drawbar
ChassisFuel tank forming the base frame
Running gearSingle axle, leaf springs, mudguards
CouplingBall or ring coupling, with safety chain
Road lightingTail, brake and indicator lights
CanopyLockable steel, louvred ventilation
AccessPersonnel door and control panel door
LiftingCrane points on the chassis frame
LashingTie-down points for flatbed transport
FuelBase tank, fill point outside the canopy
PowerkVA prime and standby, quoted per project
Voltage400 / 230 V, 50 or 60 Hz, per project
EngineDiesel, as per the set selected
AlternatorBrushless, as per the set selected
FinishPolyurethane paint, white canopy on black base
DownloadDownload pdf
Detail Information
Row of canopy diesel generator sets mounted on two-wheel road trailers

Mobile diesel power · trailer mounted

Mobile Diesel Generator Set on a Two-Wheel Road Trailer

A canopy generator set built onto a road trailer: engine, alternator, base tank and controls on one chassis that tows behind a pickup. It is the same set we would build onto a skid or into a container, mounted for a site that has no address yet.

Everything travels with the unit. Fuel sits in the base tank, the battery and control panel are on the frame behind lockable doors, and there is no bund to cast, no plinth to level and nothing to lift onto a truck bed before the set can run.

  • Trailertwo wheels
  • Canopylockable steel
  • Basetank in chassis
  • kVAper project

Four decisions

What changes when the set goes on wheels

Nose weight, not luck

The axle sits behind the centre of gravity, so the drawbar carries a controlled share of the load and the trailer follows the tow vehicle instead of steering it. A set that is simply bolted to a chassis and given wheels will sway at the first crosswind.

The base tank is the chassis

The fuel tank forms the base frame the set sits on. That is why the unit is low and compact: the weight of the fuel, engine and alternator sits below the axle line rather than on top of a separate skid.

Canopy braced for the road

Doors, hinges and louvre banks are braced against the vibration a trailer sees on a site track, because the failure mode of a road-going set is not the engine — it is a panel cracking at a hinge after a season of towing.

Tows, lifts, ties down

Coupling and safety chain for the road, crane points on the frame for unloading, and lashing points for the times it travels on a flatbed instead of behind a pickup.

How it is built

Four blocks, set to running gear

The set is the same one we build for a plant room. What is added underneath is a base tank, a canopy and a trailer that has to behave at road speed.

01

The set

Engine and alternator on a common bed, built to the same specification as the sets in our diesel generator range. Nothing is derated for the trailer: the set is the set.

02

Base tank

A steel base tank under the bed carries the fuel and stiffens the whole assembly. The fill point sits outside the canopy, so the unit is refuelled without opening a door.

03

Canopy

Lockable steel canopy with louvred ventilation, a personnel door for service and a separate door for the control panel. Weatherproof, not acoustic, unless an acoustic canopy is quoted.

04

Running gear

Chassis, single axle on leaf springs, mudguards, drawbar with coupling and safety chain, and road lighting wired to the towing vehicle.

Axle position, base tank chassis and braced canopy on a mobile generator trailer

Specification

What is fixed, and what is quoted per project

The trailer build below is the same on every unit. Power, voltage and the tank size are quoted against the load the set has to carry.

Mounting
Two-wheel road trailer with A-frame drawbar
Chassis
Fabricated steel, fuel tank forming the base
Running gear
Single axle, leaf springs, mudguards
Coupling
Ball or ring coupling, with safety chain
Road lighting
Tail, brake and indicator lights
Canopy
Lockable steel, louvred ventilation, access doors
Lifting and lashing
Crane points and tie-down points on the frame
Power
Selected per project, kVA prime and standby
Voltage
400 / 230 V, 50 or 60 Hz, per project
Finish
Polyurethane paint, white canopy on black base

Power is not published as a single range here because the trailer is sized by the wet weight of the set, not by a kVA number. Send the load and the destination, and the quotation carries the set, the axle and the tank together.

Single axle, leaf springs, drawbar coupling and road lighting on a mobile generator trailer

Where it is towed

Applications for trailer-mounted power

01

Construction sites

Site offices, hoists, dewatering pumps and welfare units, moved as the site progresses rather than rewired each time.

02

Rental fleets

Delivered and collected behind a pickup, with the fuel and the controls already on the unit and no bund or plinth left behind.

03

Events

Sound, lighting and refrigeration for shows and temporary venues, where the set has to stand away from the audience and still be quiet enough to talk over.

04

Telecom sites

Temporary and off-grid base stations, including sites waiting for a permanent supply to be connected.

05

Flood and emergency response

Pumping, lighting and temporary shelter supply, towed in after the water has arrived and the roads are the only route in.

06

Remote camps

Mining, oil field and exploration camps where the set is the supply, not the standby, and the nearest workshop is a day away.

Trailer generator set applications: construction, rental, events, telecom, flood response and remote camps

Honest limits

When a trailer is the wrong answer

The three cases below are quoted as a skid, a flatbed move or an acoustic enclosure rather than as a trailer, because that is the cheaper way to solve them.

A permanent installation

If the set will not move again, a skid on a concrete plinth costs less, sits lower and has no tyres to age in the sun. The trailer is worth its price when the unit moves at least a few times a year.

A long motorway move

The running gear is built for site tracks and short road transfers, not for weekly hundred-kilometre hauls. Beyond that, the unit travels on a flatbed and the trailer waits.

A residential noise limit

The standard canopy is weatherproof, not acoustic. Night-time limits next to housing need the acoustic canopy or a fixed enclosure with a specified sound pressure at a stated distance.

Selection

Five numbers size the unit

A trailer set is quoted from the load and the site, not from a picture of the canopy. These five answers decide the set, the tank and the running gear:

01

Power

kVA at prime and at standby, and the power factor of the load. A kW figure alone does not size a generator.

02

Voltage

400 / 230 V at 50 Hz, or 60 Hz for export, single or three phase, and whether the load is balanced across the phases.

03

Duty

Hours a day and days a year, continuous or standby. It decides the engine rating, the tank size and the service interval.

04

Ground

Hard standing, site track or soft field. It decides the tyres, and whether the unit needs to be levelled and chocked before it runs.

05

Climate

Ambient temperature, altitude and dust at the site. Derating for altitude and heat is calculated, not guessed.

Five selection inputs for a trailer generator set: power, voltage, duty, ground and climate

Selection questions

Before the quotation

What size set fits on a trailer?

The trailer is sized by the weight and footprint of the set, not by a fixed kVA ceiling. A 20 kVA set and a 500 kVA set both travel on two wheels, but not on the same axle, tyres or drawbar. The number that decides it is the wet weight with a full tank, which is why we quote the set and the trailer together rather than the trailer on its own.

Can it be towed on a public road?

The unit is built for the road, but what is legal depends on where it is registered: lighting, coupling type, mudguards, brakes and speed rating are set by local type approval, and the thresholds differ between countries. Tell us the destination and we build the lighting and coupling to that specification; where brakes are required above a weight threshold, they are quoted as part of the trailer.

How is it earthed on site?

There is an earthing terminal on the frame, and the set is earthed to a site rod or to the installation earth bar. How the neutral is bonded depends on the earthing system the site uses, so that is decided with the electrical contractor before commissioning rather than assumed at the factory.

Tell us the load and the destination

kVA, voltage, duty and where the unit will be towed are enough to quote the set, the tank and the trailer as one unit. The rest of the range is on the product index.

Send the load details
Related Products
    Please send your message to us
    *Email
    *Phone
    *Title
    *Content
    Upload
    • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.