Perkins powered · 7 - 1800 kW
Perkins Series Diesel Generator Set from 7 kW to 1800 kW
The Perkins series diesel generator set covers the whole Perkins line in one catalogue: 400, 1100, 1200/1500, 2000 and 4000 series engines from 1.1 L to 61.2 L, three to sixteen cylinders, and 7 kW to 1800 kW of prime power. One supplier for a 9 kVA telecom set and an 1800 kW data centre standby means one spare parts policy, one service procedure and one engineering contact across a fleet, which is the reason most of our repeat buyers standardise on it — see the full Perkins diesel generator range.
Each set is assembled on a fabricated skid, wired to an automatic start control panel and load tested before shipment. Open frame, soundproof canopy and containerised builds are available at 50 Hz or 60 Hz, with voltage and phase matched to the site.
- 7 - 1800kW prime power
- 1.1 - 61.2litres displacement
- 3 - 16cylinders
- 200g/kWh fuel from, at rated load
Why this platform
One engine range, from 9 kVA to 2250 kVA
Genuine Perkins base engine
Perkins has supplied diesel engines for more than eighty years and builds the 400 through 4000 series in volume, so parts availability and service documentation are not a project risk. The engine model on the nameplate tells you exactly which build you have.
Fuel burn from 200 g/kWh
Specific consumption across the model list runs from 200 to 220 g/kWh at rated load. On a 300 kW prime rated set that is roughly 60 kg per hour, so day-tank autonomy should be calculated against the load profile rather than the nameplate.
Ratings that follow the market
Model numbers follow the kVA class used in the Chinese market, while the specification columns are kW at 0.8 power factor. Both are stated on the page so an export buyer can quote either without conversion errors.
Built to ISO 3046 and ISO 8528
Ratings, governing and load acceptance follow ISO 3046 and ISO 8528 practice, referenced to -10 to 40 degrees Celsius ambient and up to 60 percent relative humidity.
Enclosure formats
Three enclosure formats, one base engine
Open frame for plant rooms and containerised power stations, soundproof canopy where noise limits apply, and ISO container builds for sea freight. Engine, alternator and control panel stay the same across formats, so spare parts, wiring diagrams and operating procedures carry over from one build to the next.
Product power parameters
Power range by Perkins engine series
Five engine series carry the range. Pick the series by duty first, then the rating; the model list further down gives engine model, fuel consumption, dimensions and weight for every build.
Prime power figures are the lowest and highest rating offered within each series; derating applies for altitude and ambient temperature above the reference conditions.
Complete range
Perkins series genset model list and specifications
Forty-three listings from 7 kW to 1800 kW prime power at 0.8 power factor. Where the same rating appears twice, the two rows are different engine builds of the same set; dimensions and weight refer to the open frame set without fuel tank.
Standby ratings are limited to the duration of a utility outage and are not continuous ratings. Voltage, frequency and phase are configured per project. Capacity is verified on a load bank before handover — see how load bank testing works and the spare parts list worth stocking for a fleet of this size.
Product application scenarios
Where the Perkins series is specified
01
Telecom and retail
7 to 80 kW sets for base stations, shops and small offices, where a compact footprint and a single-phase option matter more than headline output.
02
Healthcare and water
Standby for clinics, laboratories and pumping stations between 100 and 300 kW, with automatic transfer and remote alarm reporting.
03
Construction and rental
Site power for 24 to 200 kW duties, with skid-mounted builds that survive transport and a control panel that rental fleets can standardise on.
04
Commercial buildings
Standby for offices, hotels and shopping centres in the 200 to 650 kW band, sized against lift, HVAC and life-safety loads.
05
Data centres
N+1 standby from 600 to 1800 kW on the 4000 series, with 10-second start, load acceptance and paralleling for hall-level redundancy.
06
Marine and port
Shipborne auxiliary and shore-side supply, including yard power for shipyards and repair berths.
Testing and handover
Load tested before it leaves the factory
Every set is assembled on its skid, wired to the control panel and run on a load bank before shipment. Insulation resistance and winding checks, governor and AVR setting, safety shutdown verification and a stepped load test are recorded against the serial number, and the test sheet travels with the unit.
Where a project requires it, third-party witness testing, a documented fuel consumption curve and a site acceptance procedure are agreed in the contract.
Selection questions
Choosing the right rating
Why do the model names not match the kW figures?
The QD number follows the kVA rating used in the Chinese market, while the specification columns are in kW at 0.8 power factor. QD-2250P is therefore 2250 kVA class, rated 1800 kW prime and 1980 kW standby. For export enquiries it is safer to quote the kW figure and the required voltage.
Which Perkins series should a 300 kW project use?
At 300 kW the choice sits between the 1606 and 1506 six-cylinder builds in the 8.8 litre class, or stepping up to the 2206 at 13 litres for heavier load cycles. The larger displacement costs more weight and floor space but holds block loads and continuous duty more comfortably, so the duty cycle rather than the rating should drive the decision.
Can these sets be supplied to EU or US emissions requirements?
Perkins builds the same engine families to several emissions tiers. The build supplied is agreed at order stage against the destination market, and the engine model on the nameplate identifies the tier. Where a project needs a specific approval, state it in the enquiry so the correct build is quoted rather than a standard set.
Need a specific rating, voltage or enclosure?
Send the site conditions and load profile. We will confirm the rating from this range, or size a custom build around the same Perkins engine.
Browse Perkins generator sets